Načítavam...
Prázdny
Váš košík
Facebook

Footbalance

SlovenskyEnglish
 Defibrilator ME PAD polo-aický
 Defibrilator ME PAD polo-aický Defibrilator ME PAD polo-aický

Defibrilator ME PAD polo-aický

The
ME PAD is semi- aic defibrillator to help during sudden cardiac
death.

5 Years Warranty

Recording of up to 5... čítať viac...

Nákup
Cena vrátane 20% DPH
141480
ks

The ME PAD is semi- aic defibrillator to help during sudden cardiac death.
5 Years Warranty
Recording of up to 5 operations of 3 hours duration each on internal SD card
Including pads for adults
(up to 30 months storability)
Including lithium battery (up to 5 years storability)
Transportation bag and pads for pediatric (optional)
Fulfills military standarad MIL-STD-810G
Automatic volume adjustment to the surrounding volume
Emergency change to pediatric use (below 25kg)
without changing pads

Technické špecifikácie

ME PAD can be used at any place. The user gets all the necessary assistance as a voice instruction whereas voice volume is aically adjusted to the ambient noise.
Up to five operations of three hours of duration can be recorded on the internal SD memory card. At any time all the important data such as heart rhythm, energy output, time, etc. are available for the post-analysis.

In addition to the aic power switch while using children pads, the output can be lowered manually. Thus children can be treated in emergency cases even if pediatric electrodes are not available. In daily, weekly and monthly intervals a test program is performed.

All functions including battery performance and durability of the electrodes are aically checked. An alarm will be given in case of errors.

The software of ME PAD is programmed according to the current guidelines of the ERC.
The user is instructed through the entire resuscitation.
The long-life Li-ion battery guarantees a standby time of up to five years or up to 200 shocks at full power.

Technické špecifikácie



Output Energy Adult - 150 Joule at 50 Ω

Pediatric - 50 Joule at 50 Ω (common usage)

Charging Time less than 8 seconds

Charging Time after CPR finished at least 8 seconds

Waveform E-cube two-phase (truncated expotential type)

Acquired ECG Lead Lead II

Frequency Response 1 Hz to 30 Hz

Impendance Range 25 Ω to 175 Ω

(shock will not be delivered if the patient’s impedance is beyond this range)

Shockable Rhythms Ventricular Fibrillation or Fast Ventricular

Fibrillation

Sensitivity and Specificity

meets ANSI/AAMI DF80 guidelines

Control Devices Power Button, i-Button, Shock Button, Adult/

Pediatric Selection Switch

Status LCD Displays device status, battery level and pads


status

Speaker Plays back voice instructions. The CU-SP1

analyzes the ambient noise level during a treatment operation. If ambient noise level is

high, it aically increases the voice instructions volume so that you can hear them

clearly.


Auto Power On Self-Test, Run-time Self-Test

Daily, Weekly, and Monthly Self-Test

Manual

Battery Pack Insertion Test (done when the user

inserts the battery pack into the battery pack compartment of the device)

Disposable Battery Pack

Battery Type 12V DC, 4.2Ah LiMnO2, Disposable: Long-life


Capacity

At least 200 shocks for a new battery or 8 hours of operating time at room temperature


Standby Life

(After inserting battery)

At least 5 years from the date of manufacture if stored and maintained in accordance with the

instructions in this document.


Temperature Ranges

Operating: 0° ~ 43° C

Storage: -20° ~ 60° C


Adult Defibrillation Pads

Electrode Area: 120 cm²

Cable Length: Total 120 cm (Inside the pouch:95 cm, Outside the pouch: 25 cm)


Shelf life: Up to 30 months from the date of manufacture


Pediatric Defibrillation

Pads

Electrode Area: 46,43 cm²

Cable Length: Total 120 cm (Inside the pouch: 80 cm, Outside the pouch: 40 cm)

Shelf life: Up to 24 months from the date of manufacture


Internal Memory Data


Capacity 5 individual treatments, up to 3 hours per treatment

SD Card

External memory. Data may be copied from the internal memory to the SD Card

IrDA For PC communications


Sealing meets DIN EN 60529: IP55

ESD meets EN 61000-4-2:2001

EMI (Radiated) meets EN 60601-1-2 limits, method EN

55011:2007 + A2:2007, Group 1, Class B

EMI (Immunity)

meets IEC 60601-1-2 limits, method EN 61000-

4-3:2006 +A1:2008 Level 3

(10V/m 80MHz to 2500MHz)

Vibration Operating: Meets MIL-STD-810G Fig.514.6E-1,

random

Standby: Meets MIL-STD-810G Fig.514.6E-2,

swept sine(helicopter)

Altitude 0 to 15,000 feet (operational and storage)

Drop withstands 1.2-meter drop to any edge, corner, or surface

Environmental

Conditions

Operation: 0° ~ 43° C, 5% ~ 95% (non

condensing)

Standby: 0° ~ 43° C, 5% ~ 95% (non

condensing)

Transport: -20° ~ 60° C, 5% ~ 95% (non

condensing), device only

Languages German, English, French, Danish, Spanish,

Norwegian, Italian, Czech, Portuguese, Greek,

Swedish, Dutch

More languages are planned

Dimensions 260 x 256 x 69,5 mm (WxLxH)

Weight 2,4 kg including battery pack & pads